Converter: DC/DC; GAPTEC Electronic; Power: 60W

Manufacturer
Type of converterDC/DC
Power60W
MountingTHT
Symbol Uinsul Uin Output voltage Iout Uout2 Iout2 Efficiency Manufacturer series Protection Body dim. Operating temperature Number of outputs
[kV DC] [V DC] [V DC] [A] [V DC] [A] [%] [mm] [°C]
60DAW4-2405S1.6 1.6 9...36 5 12 - - 91 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 1
60DAW4-2412D1.6 1.6 9...36 12 5 -12 -5 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 2
60DAW4-2412S1.6 1.6 9...36 12 5 - - 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 1
60DAW4-2415D1.6 1.6 9...36 15 4 -15 -4 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 2
60DAW4-2415S1.6 1.6 9...36 15 4 - - 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 1
60DAW4-4805S1.6 1.6 18...75 5 12 - - 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 1
60DAW4-4812D1.6 1.6 18...75 12 5 -12 -5 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 2
60DAW4-4812S1.6 1.6 18...75 12 5 - - 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 1
60DAW4-4815D1.6 1.6 18...75 15 4 -15 -4 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 2
60DAW4-4815S1.6 1.6 18...75 15 4 - - 92 60DAW4_1.6 anti-overload OPP, short circuit protection SCP, overheating OTP 50.8x25.4x17.2 -40...76 1
60DDW-1205D3 3 9...18 5 5 -5 -5 81 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-1205S3 3 9...18 5 10 - - 80 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-1212D3 3 9...18 12 2.5 -12 -2.5 87 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-1212S3 3 9...18 12 5 - - 85 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-1215D3 3 9...18 15 2 -15 -2 87 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-1215S3 3 9...18 15 4 - - 86 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-2403S1.5 1.5 18...36 3.3 14 - - 89 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-2405D3 3 18...36 5 5 -5 -5 81 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-2405S1.5 1.5 18...36 5 12 - - 90 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-2405S3 3 18...36 5 10 - - 81 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-2412D3 3 18...36 12 2.5 -12 -2.5 87 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-2412S1.5 1.5 18...36 12 5 - - 90 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-2412S3 3 18...36 12 5 - - 88 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-2415D3 3 18...36 15 2 -15 -2 88 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-2415S1.5 1.5 18...36 15 4 - - 90 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-2415S3 3 18...36 15 4 - - 88 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-4803S1.5 1.5 36...75 3.3 14 - - 89 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-4805D3 3 36...72 5 5 -5 -5 82 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-4805S1.5 1.5 36...75 5 12 - - 90 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-4805S3 3 36...72 5 10 - - 82 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-4812D3 3 36...72 12 2.5 -12 -2.5 87 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-4812S1.5 1.5 36...75 12 5 - - 90 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-4812S3 3 36...72 12 5 - - 88 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1
60DDW-4815D3 3 36...72 15 2 -15 -2 87 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 2
60DDW-4815S1.5 1.5 36...75 15 4 - - 90 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 51.3x51.3x17.3 -40...85 1
60DDW-4815S3 3 36...72 15 4 - - 88 60DDW_3 undervoltage-lockout UVLO, short circuit protection SCP, overheating OTP 66.5x76.7x27.2 -40...85 1