DC/DC converters, CHB series by CINCON

Manufacturer
Type of converterDC/DC
Number of outputs1
Symbol Operating temperature Protection Body dim. Dimensions Manufacturer series Power Uinsul Uin Iout Efficiency Switch. freq. Application Output voltage Conform to the norm Additional functions Features Case Mounting
[°C] [mm] [W] [kV DC] [V DC] [A] [%] [Hz] [V DC]
CHB50W-24S33 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 9...36 10 78 300k - 3.3 - adjustable output current level - - THT
CHB50W-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 9...36 10 81 300k - 5 - adjustable output current level - - THT
CHB50W-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 9...36 4.16 83 300k - 12 - adjustable output current level - - THT
CHB50W-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 9...36 3.33 85 300k - 15 - adjustable output current level - - THT
CHB50W-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 9...36 2.08 84 300k - 24 - adjustable output current level - - THT
CHB50W-24S48 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 9...36 1.78 83 300k - 48 - adjustable output current level - - THT
CHB50W-48S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 18...75 10 83 300k - 5 - adjustable output current level - - THT
CHB50W-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 18...75 4.16 85 300k - 12 - adjustable output current level - - THT
CHB50W-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50W 50 1.5 18...75 2.08 86 300k - 24 - adjustable output current level - - THT
CHB75W-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 9...36 15 82 300k - 5 - adjustable output current level - - THT
CHB75W-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 9...36 6.25 83 300k - 12 - adjustable output current level - - THT
CHB75W-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 9...36 15 84 300k - 15 - adjustable output current level - - THT
CHB75W-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 9...36 3.12 84 300k - 24 - adjustable output current level - - THT
CHB75W-48S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 18...75 15 83 300k - 5 - adjustable output current level - - THT
CHB75W-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 18...75 6.25 84 300k - 12 - adjustable output current level - - THT
CHB75W-48S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 18...75 5 85 300k - 15 - adjustable output current level - - THT
CHB75W-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 18...75 3.12 85 300k - 24 - adjustable output current level - - THT
CHB75W-48S48 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75W 75 1.5 18...75 1.56 84 300k - 48 - adjustable output current level - - THT
CHB100W-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 9...36 6.7 87 250k - 15 - adjustable output current level - - THT
CHB100W-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 9...36 4.17 87.5 250k - 24 - adjustable output current level - - THT
CHB100W-24S48 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 9...36 2.08 82.5 250k - 48 - adjustable output current level - - THT
CHB100W-48S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 18...75 20 86 250k - 5 - adjustable output current level - - THT
CHB100W-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 18...75 8.3 87.5 250k - 12 - adjustable output current level - - THT
CHB100W-48S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 18...75 6.7 88 250k - 15 - adjustable output current level - - THT
CHB100W-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 18...75 4.17 89 250k - 24 - adjustable output current level - - THT
CHB150-110S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 2. CHB150-110S 150 2.25 66...160 30 92.5 200k railway industry 5 EN 50155 adjustable output current level - - THT
CHB150-110S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 2. CHB150-110S 150 2.25 66...160 12.5 92.5 200k railway industry 12 EN 50155 adjustable output current level - - THT
CHB150-110S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 2. CHB150-110S 150 2.25 66...160 6.5 92 200k railway industry 24 EN 50155 adjustable output current level - - THT
CHB150W-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 9...39 30 87 250k - 5 - adjustable output current level - - THT
CHB150W-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 9...39 12.5 88 250k - 12 - adjustable output current level - - THT
CHB150W-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 9...39 10 87 250k - 15 - adjustable output current level - - THT
CHB150W-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 9...39 6.5 88 250k - 24 - adjustable output current level - - THT
CHB150W-24S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 9...39 3.12 84 250k - 48 - adjustable output current level - - -
CHB150W-48S3V3 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 18...75 30 88 250k - 3.3 - adjustable output current level - - THT
CHB150W-48S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 18...75 10 90 250k - 15 - adjustable output current level - - THT
CHB150W-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 18...75 6.5 90 250k - 24 - adjustable output current level - - THT
CHB150W-48S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 3. CHB150W 150 1.5 18...75 3.12 86 250k - 48 - adjustable output current level - - -
CHB150W8-36S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 4. CHB150W8 150 1.5 9...75 12.5 89.5 200 - 12 - adjustable output current level - - THT
CHB150W8-36S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 4. CHB150W8 150 1.5 9...75 6.25 89 200 - 24 - adjustable output current level - - THT
CHB150W12-72S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 25 90 480 railway industry 5 EN 50155 adjustable output current level - - THT
CHB150W12-72S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 6.25 90 480 railway industry 12 EN 50155 adjustable output current level - - THT
CHB150W12-72S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 10 90 480 railway industry 15 EN 50155 adjustable output current level - - THT
CHB150W12-72S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 6.25 89 480 railway industry 24 EN 50155 adjustable output current level - - THT
CHB150W12-72S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 3.2 89 480 railway industry 48 EN 50155 adjustable output current level - - THT
CHB150W12-72S05N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 25 90 480 railway industry 5 EN 50155 adjustable output current level - - THT
CHB150W12-72S12N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 12.5 90 480 railway industry 12 EN 50155 adjustable output current level - - THT
CHB150W12-72S15N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 10 90 480 railway industry 15 EN 50155 adjustable output current level - - THT
CHB150W12-72S24N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 6.25 89 480 railway industry 24 EN 50155 adjustable output current level - - THT
CHB150W12-72S48N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 150 3 14...160 3.2 89 480 railway industry 48 EN 50155 adjustable output current level - - THT
CHB200W12-72S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 16.7 90 480 railway industry 12 EN 50155 adjustable output current level - - THT
CHB200W12-72S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 13.5 89 480 railway industry 15 EN 50155 adjustable output current level - - THT
CHB200W12-72S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 8.4 88 480 railway industry 24 EN 50155 adjustable output current level - - THT
CHB200W12-72S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 4.2 89 480 railway industry 48 EN 50155 adjustable output current level - - THT
CHB200W12-72S12N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 16.7 90 480 railway industry 12 EN 50155 adjustable output current level - - THT
CHB200W12-72S15N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 13.5 89 480 railway industry 15 EN 50155 adjustable output current level - - THT
CHB200W12-72S24N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 8.4 88 480 railway industry 24 EN 50155 adjustable output current level - - THT
CHB200W12-72S48N -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 5. CHB150W12 200 3 14...160 4.2 89 480 railway industry 48 EN 50155 adjustable output current level - - THT
CHB200W-110S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 6. CHB200W-110S 200 3 43...160 8.3 89 300k railway industry 24 EN 50155 adjustable output current level - - THT
CHB200W-110S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 6. CHB200W-110S 200 3 43...160 4.2 91 300k railway industry 48 EN 50155 adjustable output current level - - THT
CHB200W-110S05CMFC -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x76.2x38.5 Fig. 7. CHB200W-110S 200 3 43...160 40 87.5 300k railway industry 5 EN 50155 adjustable output current level - - THT
CHB200W-110S12CMFC -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x76.2x38.5 Fig. 7. CHB200W-110S 200 3 43...160 16.7 90.5 300k railway industry 12 EN 50155 adjustable output current level - - THT
CHB200W-110S24CMFC -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x76.2x38.5 Fig. 7. CHB200W-110S 200 3 43...160 8.3 89 300k railway industry 24 EN 50155 adjustable output current level - - THT
CHB200W-110S28CMFC -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x76.2x38.5 Fig. 7. CHB200W-110S 200 3 43...160 7.14 89 300k railway industry 28 EN 50155 adjustable output current level - - THT
CHB200W-110S48CMFC -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x76.2x38.5 Fig. 7. CHB200W-110S 200 3 43...160 4.2 90.5 300k railway industry 48 EN 50155 adjustable output current level - - THT
CHB200W-110S05CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 8. CHB200W-110S 200 3 43...160 40 87.5 300k railway industry 5 EN 50155 adjustable output current level - - THT
CHB200W-110S12CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 8. CHB200W-110S 200 3 43...160 16.7 90.5 300k railway industry 12 EN 50155 adjustable output current level - - THT
CHB200W-110S24CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 8. CHB200W-110S 200 3 43...160 8.3 89 300k railway industry 24 EN 50155 adjustable output current level - - THT
CHB200W-110S28CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 8. CHB200W-110S 200 3 43...160 7.14 89 300k railway industry 28 EN 50155 adjustable output current level - - THT
CHB200W-110S48CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 8. CHB200W-110S 200 3 43...160 4.2 90.5 300k railway industry 48 EN 50155 adjustable output current level - - THT
CHB200W-24S3V3 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 10...36 50 87 300k - 3.3 - adjustable output current level - - THT
CHB200W-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 10...36 40 87 250k - 5 - adjustable output current level - - THT
CHB200W-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 10...36 16.7 86 250k - 12 - adjustable output current level - - THT
CHB200W-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 10...36 8.3 87 250k - 24 - adjustable output current level - - THT
CHB200W-24S28 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 10...36 7.14 88.5 250k - 28 - adjustable output current level - - THT
CHB200W-24S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 10...36 4.2 86 250k - 48 - adjustable output current level - - THT
CHB200W-48S3V3 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 18...75 50 88 250k - 3.3 - adjustable output current level - - THT
CHB200W-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 18...75 16.7 88 250k - 12 - adjustable output current level - - THT
CHB200W-48S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 18...75 13.3 88 250k - 15 - adjustable output current level - - THT
CHB200W-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB200W-110S 200 1.5 18...75 8.3 88 250k - 24 - adjustable output current level - - THT
CHB300-300S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 10. CHB300-300S 300 3 180...425 6.25 90 300k - 48 - adjustable output current level - - THT
CHB300-300S24-CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 11. CHB300-300S 300 3 180...425 12.5 90 300k - 24 - adjustable output current level - - THT
CHB300W-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 9...36 60 88 220k - 5 - adjustable output current level - - THT
CHB300W-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 9...36 25 91 220k - 12 - adjustable output current level - - THT
CHB300W-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 9...36 20 91 220k - 15 - adjustable output current level - - THT
CHB300W-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 9...36 12.5 88 220k - 24 - adjustable output current level - - THT
CHB300W-24S28 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 9...36 10.7 88.5 220k - 28 - adjustable output current level - - THT
CHB300W-24S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 9...36 6.25 88 220k - 48 - adjustable output current level - - THT
CHB300W-48S15 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 18...75 20 92 220k - 15 - adjustable output current level - - THT
CHB300W-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 18...75 12.5 89 220k - 24 - adjustable output current level - - THT
CHB300W-48S28 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 18...75 10.7 89.5 220k - 28 - adjustable output current level - - THT
CHB300W-110S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W-110S 300 3 43...160 60 88 300k railway industry 5 EN 50155 adjustable output current level - - THT
CHB300W-110S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W-110S 300 3 43...160 25 90 300k railway industry 12 EN 50155 adjustable output current level - - THT
CHB300W-110S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W-110S 300 3 43...160 12.5 89 300k railway industry 24 EN 50155 adjustable output current level - - THT
CHB300W-110S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x12.7 Fig. 12. CHB300W-110S 300 3 43...160 6.25 91 300k railway industry 48 EN 50155 adjustable output current level - - THT
CHB300W-110S24CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 11. CHB300W-110S 300 3 43...160 12.5 89 300k railway industry 24 EN 50155 adjustable output current level - - THT
CHB300W-110S48CMFD -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 165x78.6x40 Fig. 11. CHB300W-110S 300 3 43...160 6.25 90.5 300k railway industry 48 EN 50155 adjustable output current level - - THT
CHB350-24S3V3 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 18...36 70 88 300k - 3.3 - adjustable output current level - - THT
CHB350-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 18...36 70 89 300k - 5 - adjustable output current level - - THT
CHB350-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 18...36 29.2 90.5 330k - 12 - adjustable output current level - - THT
CHB350-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 18...36 14.6 89 330k - 24 - adjustable output current level - - THT
CHB350-24S28 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 18...36 12.5 90.5 330k - 28 - adjustable output current level - - THT
CHB350-24S48 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 18...36 7.3 92 330k - 48 - adjustable output current level - - THT
CHB350-48S3V3 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 36...75 70 89 300k - 3.3 - adjustable output current level - - THT
CHB350-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 36...75 29.2 92.5 330k - 12 - adjustable output current level - - THT
CHB350-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 36...75 14.6 91.5 330k - 24 - adjustable output current level - - THT
CHB350-48S28 -40...100 anti-overvoltage OVP, short circuit protection SCP, overheating OTP 57.9x61x13.2 Fig. 9. CHB350 350 1.5 36...75 7.3 92 330k - 28 - adjustable output current level - - THT
CHB100-110S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 3 66...160 8.3 86.5 250k - 12 - adjustable output current level - - THT
CHB100-110S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 3 66...160 4.17 87.5 250k - 24 - adjustable output current level - - THT
CHB100-110S48 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 3 66...160 2.08 89 250k - 48 - adjustable output current level - - THT
CHB100-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 1.5 18...36 20 84 500k - 5 - adjustable output current level - - THT
CHB100-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 1.5 18...36 8.3 87 500k - 12 - adjustable output current level - - THT
CHB100-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 1.5 18...36 6.7 88 500k - 15 - adjustable output current level - - THT
CHB100-24S24N -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100 100 1.5 18...36 4.17 87 500k - 24 - adjustable output current level - - THT
CHB100W-24S05N -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB100W 100 1.5 9...36 20 84.5 250k - 5 - adjustable output current level - - THT
CHB200W-110S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 6. CHB200W-110S 200 3 43...160 40 89 300k - 5 - adjustable output current level - - THT
CHB200W-110S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 6. CHB200W-110S 200 3 43...160 16.7 91 300k - 12 - adjustable output current level - - THT
CHB200W-110S28 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 6. CHB200W-110S 200 3 43...160 7.14 89 300k - 28 - adjustable output current level - - THT
CHB300-300S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 10. CHB300-300S 300 3 180...425 60 89 300k - 5 - adjustable output current level - - THT
CHB300-300S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 10. CHB300-300S 300 3 180...425 25 88 300k - 12 - adjustable output current level - - THT
CHB300-300S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 10. CHB300-300S 300 3 180...425 12.5 90 300k - 24 - adjustable output current level - - THT
CHB300-300S28 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 10. CHB300-300S 300 3 180...425 10.7 90 300k - 28 - adjustable output current level - - THT
CHB300W-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 18...75 25 92 220k - 12 - adjustable output current level - - THT
CHB300W-48S48 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 12. CHB300W 300 1.5 18...75 6.25 90 220k - 48 - adjustable output current level - - THT
CHB350-24S12-L -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 13. CHB350 350 1.5 18...36 29.2 90.5 330k - 12 - adjustable output current level - - -
CHB50-12S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 9...18 10 83 400k - 5 - adjustable output current level - - THT
CHB50-12S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 9...18 4.16 87 400k - 12 - adjustable output current level - - THT
CHB50-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 18...36 10 85 400k - 5 - adjustable output current level - - THT
CHB50-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 18...36 4.16 88 400k - 12 - adjustable output current level - - THT
CHB50-24S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 18...36 3.33 88 400k - 15 - adjustable output current level - - THT
CHB50-24S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 18...36 2.08 88 400k - 24 - adjustable output current level - - THT
CHB50-48S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 36...75 10 84 300k - 5 - adjustable output current level - - THT
CHB50-48S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 36...75 4.16 88 300k - 12 - adjustable output current level - - THT
CHB50-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB50 50 1.5 36...75 2.08 89 300k - 24 - adjustable output current level - - THT
CHB75-12S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 9...18 15 83 400k - 5 - adjustable output current level - - THT
CHB75-12S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 9...18 6.25 87 400k - 12 - adjustable output current level - - THT
CHB75-12S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 9...18 5 86 400k - 15 - adjustable output current level - - THT
CHB75-12S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 9...18 3.13 87 400k - 24 - adjustable output current level - - THT
CHB75-24S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 18...36 15 84 400k - 5 - adjustable output current level - - THT
CHB75-24S05N -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 18...36 15 84 400k - 5 - adjustable output current level - - THT
CHB75-24S12 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 18...36 6.25 88 400k - 12 - adjustable output current level - - THT
CHB75-24S12N -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 18...36 6.25 88 400k - 12 - adjustable output current level - - -
CHB75-48S05 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 36...75 15 84 300k - 5 - adjustable output current level - - THT
CHB75-48S15 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 36...75 5 88 300k - 15 - adjustable output current level - - THT
CHB75-48S24 -40...100 anti-overvoltage OVP, short circuit protection SCP 57.9x61x12.7 Fig. 1. CHB75 75 1.5 36...75 3.13 89 300k - 24 - adjustable output current level - - THT
CHB200W1272S12CMFD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 16.7 89.5 480k - 12 - disturbance filter - - -
CHB200W1272S15CMFD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 13.5 89.5 480k - 15 - disturbance filter - - -
CHB200W1272S24CMFD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 8.4 88 480k - 24 - disturbance filter - - -
CHB200W1272S48CMFD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 4.2 88.5 480k - 48 - disturbance filter - - -
CHB200W1272S12NCMF -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 16.7 89.5 480k - 12 - disturbance filter - - -
CHB200W1272S15NCMF -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 13.5 89.5 480k - 15 - disturbance filter - - -
CHB200W1272S24NCMF -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 8.4 88 480k - 24 - disturbance filter - - -
CHB200W1272S48NCMF -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x39.5x78.6 Fig. 14. CHB200W12-72S CMFD 200 4.2 14...160 4.2 88.5 480k - 48 - disturbance filter - - -
CHB200W1272S12CMHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 16.7 89.5 480k - 12 - disturbance filter - - -
CHB200W1272S15CMHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 13.5 89.5 480k - 15 - disturbance filter - - -
CHB200W1272S24CMHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 8.4 88 480k - 24 - disturbance filter - - -
CHB200W1272S48CMHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 4.2 88.5 480k - 48 - disturbance filter - - -
CHB200W1272S12NCHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 16.7 89.5 480k - 12 - disturbance filter - - -
CHB200W1272S15NCHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 13.5 89.5 480k - 15 - disturbance filter - - -
CHB200W1272S24NCHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 8.4 88 480k - 24 - disturbance filter - - -
CHB200W1272S48NCHS -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x67x96.5 Fig. 15. CHB200W12-72S CMFD 200 4.2 14...160 4.2 88.5 480k - 48 - disturbance filter - - -
CHB200W1272S12CMHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 16.7 89.5 480k - 12 - disturbance filter - - -
CHB200W1272S15CMHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 13.5 89.5 480k - 15 - disturbance filter - - -
CHB200W1272S24CMHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 8.4 88 480k - 24 - disturbance filter - - -
CHB200W1272S48CMHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 4.2 89.5 480k - 48 - disturbance filter - - -
CHB200W1272S12NCHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 16.7 89.5 480k - 12 - disturbance filter - - -
CHB200W1272S15NCHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 13.5 89.5 480k - 15 - disturbance filter - - -
CHB200W1272S24NCHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 8.4 88 480k - 24 - disturbance filter - - -
CHB200W1272S48NCHD -40...95 over current OCP, anti-overvoltage OVP, short circuit protection SCP 177.2x76.2x96.5 Fig. 16. CHB200W12-72S CMFD 200 4.2 14...160 4.2 88.5 480k - 48 - disturbance filter - - -
CHB500W-24S12 -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 42 90 200k - 12 - -   Half Brick THT
CHB500W-24S12N -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 42 90 200k - 12 - -   Half Brick THT
CHB500W-24S12N-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 42 90 200k - 12 - - single-wire parallel control Half Brick THT
CHB500W-24S12-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 42 90 200k - 12 - - single-wire parallel control Half Brick THT
CHB500W-24S24 -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9.5...40 21 91 200k - 24 - - - Half Brick THT
CHB500W-24S24N -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9.5...40 21 91 200k - 24 - - - Half Brick THT
CHB500W-24S24N-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9.5...40 21 91 200k - 24 - - single-wire parallel control Half Brick THT
CHB500W-24S24-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9.5...40 21 91 200k - 24 - - single-wire parallel control Half Brick THT
CHB500W-24S28 -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 18 90 200k - 28 - - - Half Brick THT
CHB500W-24S28N -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 18 90 200k - 28 - - - Half Brick THT
CHB500W-24S28N-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 18 90 200k - 28 - - single-wire parallel control Half Brick THT
CHB500W-24S28-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 18 90 200k - 28 - - single-wire parallel control Half Brick THT
CHB500W-24S54 -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 9.26 90 200k - 54 - - - Half Brick THT
CHB500W-24S54N -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 9.26 90 200k - 54 - - - Half Brick THT
CHB500W-24S54N-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 9.26 90 200k - 54 - - single-wire parallel control Half Brick THT
CHB500W-24S54-PC -40...105 over current OCP, anti-overvoltage OVP, short circuit protection SCP 61x12.7x57.9 Fig. 17. CHB500W 500 3 9...40 9.26 90 200k - 54 - - single-wire parallel control Half Brick THT