Symbol Manufacturer's part number Insulation resistance measuring ranges Measurement Display Touchpad Resolution Test voltage AC voltage measuring range Earthing resistance measuring range Battery/ rechargeable battery IP rating Interface Conform to the norm Application Measurement memory Features Related items Equipment Kit contents AC voltage measuring accuracy Earthing resistance measuring accuracy
[Ω] [V] [V] [Ω]
MPI-535-PL WMPLMPI535 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, short circuit loop impedance, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance LCD TFT 7" yes 800x480 50/100/250/500/1k - 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 - - checks conductors polarization - WS-03 test adapter; calibration certificate; USB cable; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 - ±(2% + 3 digit) ±(3% + 8 digit)
MPI-540-ENG WMGBMPI540 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 - - checks conductors polarization - WS-03 test adapter; calibration certificate; current clamp; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 - ±0.5% ±(3% + 8 digit)
MPI-540-PV-SOLAR WMPLMPI540PVIRM1 50k...250M/100k...500M/250k...999M/500k...2G/1M...4.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, insolation, illuminance, RCD tripping current, insulation resistance, earthing resistance, temperature, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k - IP51 Bluetooth; USB; WiFi CAT IV 300V CAT V 500V EN 61010 PN EN 61326-1 PN EN 61326-2-2 for solar panels, photovoltaics - - IRM-1-MPI, WAADAAC16, WAADAAGT16P, WAADAAGT16T, WAADAAGT32C, WAADAAGT32P, WAADAAGT32T, WAADAAGT63P, WAADAAISO10C, WAADACPV, WAADALP10AKPL, WAADALP10BKPL, WAADALP1KPL, WAADAMC4, WAADAPVM1, WAADAWS03, WAADAWS04, WAAKU15, WACEGC3OKR, WACEGC4AOKR, WACEGC5AOKR, WACEGC6AOKR, WACEGC7AOKR, WACEGCPVOKR, WACEGF1AOKR, WACEGF2AOKR, WACEGF3AOKR, WACEGN1BB, WAFUTL2, WAFUTL3, WAFUTM13, WAKROBL20K01, WAKROBU20K02, WAKRORE20K02, WAKROYE20K02, WAPOZSZEKPL, WAPRZ005REBB, WAPRZ010REBB, WAPRZ015BUBBSZ, WAPRZ020REBB, WAPRZ025BUBBSZ, WAPRZ030REBBSZ, WAPRZ050YEBBSZ, WAPRZ1X2BLBB, WAPRZ1X2BUBB, WAPRZ1X2REBB, WAPRZ1X2YEBB, WAPRZLAD12SAM, WAPRZLAD230, WAPRZUSB, WASONBUOGB1, WASONG30, WASONG80V2, WASONREOGB1, WASONYEOGB1, WAZACIMA1, WAZASZ7 test adapter; calibration certificate; current clamp; soft case; mains cable; microSD 4GB memory card; crocodile clips; nylon strap; test leads; test probe x1; power supply; adapter x3; USB cable - - ±(2% + 3 digit)
MPI-520S-PL WMPLMPI520S 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, short circuit loop impedance, phase sequence, reactive power, active power, apparent power, insulation resistance, protective conductor resistance, earthing resistance LCD - - 50/100/250/500/1k 0...500 500m...1.99k battery LR14 1,5V x4 IP54 USB CAT III 600V CAT IV 300V EN 61010 - 57500 checks conductors polarization - WS-03 test adapter; calibration certificate; USB cable; neckstrap; test leads ( 3pcs.) - - ±(3% + 8 digit)
MPI-525-PL WMPLMPI525 50k...250M/500M/999M/2G/3G/9.99G RCD tripping time, short circuit loop impedance, phase sequence, RCD tripping current, insulation resistance, protective conductor resistance, earthing resistance LCD - - 50/100/250/500/1k/2.5k 0...500 500m...1.99k rechargeable battery Ni-MH 4,8V 4200mAh x1 IP54 USB CAT III 600V CAT IV 300V EN 61010 - 57500 checks conductors polarization - WS-03 test adapter; calibration certificate; soft case; USB cable; mains cable; neckstrap; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); a earth spike x2; 3 pointed electrodes; power supply AC 230V - - ±(2% + 3 digit)
MPI-530IT-PL WMPLMPI530IT 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, harmonics, short circuit loop impedance, motor's rotation direction, phase sequence, reactive power, active power, apparent power, illuminance, RCD tripping current, insulation resistance, protective conductor resistance, earthing resistance, THD, power factor LCD - - 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Ni-MH 4,8V 4200mAh x1 IP54 Bluetooth; USB CAT III 600V CAT IV 300V EN 61010 - 10000 checks conductors polarization - WS-03 test adapter; calibration certificate; soft case; USB cable; mains cable; 3 crocodile clips; mini Bluetooth keyboard; neckstrap; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); a earth spike x2; 3 pointed electrodes; power supply AC 230V - - ±(3% + 8 digit)
MPI-530-PL WMPLMPI530 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, harmonics, short circuit loop impedance, motor's rotation direction, phase sequence, reactive power, active power, apparent power, illuminance, RCD tripping current, insulation resistance, protective conductor resistance, earthing resistance, THD, power factor LCD - - 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Ni-MH 4,8V 4200mAh x1 IP54 Bluetooth; USB CAT III 600V CAT IV 300V EN 61010 - 10000 checks conductors polarization - WS-03 test adapter; calibration certificate; soft case; USB cable; mains cable; 3 crocodile clips; mini Bluetooth keyboard; neckstrap; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); a earth spike x2; 3 pointed electrodes; power supply AC 230V - - ±(3% + 8 digit)
MPI-540PV-PL WMPLMPI540PV 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 for solar panels, photovoltaics - checks conductors polarization - WS-03 test adapter; calibration certificate; current clamp; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 - ±0.5% ±(3% + 8 digit)
MPI-540-PL WMPLMPI540 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 - - checks conductors polarization - WS-03 test adapter; calibration certificate; current clamp; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 - ±0.5% ±(3% + 8 digit)
MPI-540PVS-PL WMPLMPI540PVS 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 for solar panels, photovoltaics - checks conductors polarization - WS-03 test adapter; calibration certificate; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 - ±0.5% ±(3% + 8 digit)
MPI-540PVS-IRM-1 WMPLMPI540PVSIRM1 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 for solar panels, photovoltaics - checks conductors polarization - - calibration certificate; USB cable; cable for supplying from car lighter socket; crocodile clips x3; solar radiation and temperature meter IRM-1; carrying strap; carrying case; test leads x3; 15m long test lead (blue); 30m long test lead (red); test probe x3; multi-function meter of electrical system parameters MPI-540PVS-PL ±0.5% ±(3% + 8 digit)
MPI-540S-PL WMPLMPI540S 50k...250M/500M/999M/2G/9.99G RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD LCD TFT 7" yes 800x480 50/100/250/500/1k 0...500 0...99.9k rechargeable battery Li-Ion 11,1V 3400mAh x1 IP51 Bluetooth; USB; WiFi CAT III 500V CAT IV 300V EN 61010 - - checks conductors polarization - WS-03 test adapter; calibration certificate; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 - ±0.5% ±(3% + 8 digit)