| Meter | appliance meter |
| Manufacturer | SONEL |
| RCD test | general purpose |
| Body dimensions | 288x223x75mm |
| Connectors for the country | Europe |
| Symbol | Manufacturer's part number | Insulation resistance measuring ranges | Measurement | Display | Touchpad | Resolution | Test voltage | AC voltage measuring range | Earthing resistance measuring range | Battery/ rechargeable battery | IP rating | Interface | Conform to the norm | Application | Measurement memory | Features | Related items | Equipment | Kit contents | AC voltage measuring accuracy | Earthing resistance measuring accuracy |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [Ω] | [V] | [V] | [Ω] | ||||||||||||||||||
| MPI-535-PL | WMPLMPI535 | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, short circuit loop impedance, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | - | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | - | - | checks conductors polarization | - | WS-03 test adapter; calibration certificate; USB cable; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 | - | ±(2% + 3 digit) | ±(3% + 8 digit) |
| MPI-540-ENG | WMGBMPI540 | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | - | - | checks conductors polarization | - | WS-03 test adapter; calibration certificate; current clamp; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 | - | ±0.5% | ±(3% + 8 digit) |
| MPI-540-PV-SOLAR | WMPLMPI540PVIRM1 | 50k...250M/100k...500M/250k...999M/500k...2G/1M...4.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, insolation, illuminance, RCD tripping current, insulation resistance, earthing resistance, temperature, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | - | IP51 | Bluetooth; USB; WiFi | CAT IV 300V CAT V 500V EN 61010 PN EN 61326-1 PN EN 61326-2-2 | for solar panels, photovoltaics | - | - | IRM-1-MPI, WAADAAC16, WAADAAGT16P, WAADAAGT16T, WAADAAGT32C, WAADAAGT32P, WAADAAGT32T, WAADAAGT63P, WAADAAISO10C, WAADACPV, WAADALP10AKPL, WAADALP10BKPL, WAADALP1KPL, WAADAMC4, WAADAPVM1, WAADAWS03, WAADAWS04, WAAKU15, WACEGC3OKR, WACEGC4AOKR, WACEGC5AOKR, WACEGC6AOKR, WACEGC7AOKR, WACEGCPVOKR, WACEGF1AOKR, WACEGF2AOKR, WACEGF3AOKR, WACEGN1BB, WAFUTL2, WAFUTL3, WAFUTM13, WAKROBL20K01, WAKROBU20K02, WAKRORE20K02, WAKROYE20K02, WAPOZSZEKPL, WAPRZ005REBB, WAPRZ010REBB, WAPRZ015BUBBSZ, WAPRZ020REBB, WAPRZ025BUBBSZ, WAPRZ030REBBSZ, WAPRZ050YEBBSZ, WAPRZ1X2BLBB, WAPRZ1X2BUBB, WAPRZ1X2REBB, WAPRZ1X2YEBB, WAPRZLAD12SAM, WAPRZLAD230, WAPRZUSB, WASONBUOGB1, WASONG30, WASONG80V2, WASONREOGB1, WASONYEOGB1, WAZACIMA1, WAZASZ7 | test adapter; calibration certificate; current clamp; soft case; mains cable; microSD 4GB memory card; crocodile clips; nylon strap; test leads; test probe x1; power supply; adapter x3; USB cable | - | - | ±(2% + 3 digit) |
| MPI-520S-PL | WMPLMPI520S | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, short circuit loop impedance, phase sequence, reactive power, active power, apparent power, insulation resistance, protective conductor resistance, earthing resistance | LCD | - | - | 50/100/250/500/1k | 0...500 | 500m...1.99k | battery LR14 1,5V x4 | IP54 | USB | CAT III 600V CAT IV 300V EN 61010 | - | 57500 | checks conductors polarization | - | WS-03 test adapter; calibration certificate; USB cable; neckstrap; test leads ( 3pcs.) | - | - | ±(3% + 8 digit) |
| MPI-525-PL | WMPLMPI525 | 50k...250M/500M/999M/2G/3G/9.99G | RCD tripping time, short circuit loop impedance, phase sequence, RCD tripping current, insulation resistance, protective conductor resistance, earthing resistance | LCD | - | - | 50/100/250/500/1k/2.5k | 0...500 | 500m...1.99k | rechargeable battery Ni-MH 4,8V 4200mAh x1 | IP54 | USB | CAT III 600V CAT IV 300V EN 61010 | - | 57500 | checks conductors polarization | - | WS-03 test adapter; calibration certificate; soft case; USB cable; mains cable; neckstrap; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); a earth spike x2; 3 pointed electrodes; power supply AC 230V | - | - | ±(2% + 3 digit) |
| MPI-530IT-PL | WMPLMPI530IT | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, harmonics, short circuit loop impedance, motor's rotation direction, phase sequence, reactive power, active power, apparent power, illuminance, RCD tripping current, insulation resistance, protective conductor resistance, earthing resistance, THD, power factor | LCD | - | - | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Ni-MH 4,8V 4200mAh x1 | IP54 | Bluetooth; USB | CAT III 600V CAT IV 300V EN 61010 | - | 10000 | checks conductors polarization | - | WS-03 test adapter; calibration certificate; soft case; USB cable; mains cable; 3 crocodile clips; mini Bluetooth keyboard; neckstrap; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); a earth spike x2; 3 pointed electrodes; power supply AC 230V | - | - | ±(3% + 8 digit) |
| MPI-530-PL | WMPLMPI530 | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, harmonics, short circuit loop impedance, motor's rotation direction, phase sequence, reactive power, active power, apparent power, illuminance, RCD tripping current, insulation resistance, protective conductor resistance, earthing resistance, THD, power factor | LCD | - | - | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Ni-MH 4,8V 4200mAh x1 | IP54 | Bluetooth; USB | CAT III 600V CAT IV 300V EN 61010 | - | 10000 | checks conductors polarization | - | WS-03 test adapter; calibration certificate; soft case; USB cable; mains cable; 3 crocodile clips; mini Bluetooth keyboard; neckstrap; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); a earth spike x2; 3 pointed electrodes; power supply AC 230V | - | - | ±(3% + 8 digit) |
| MPI-540PV-PL | WMPLMPI540PV | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | for solar panels, photovoltaics | - | checks conductors polarization | - | WS-03 test adapter; calibration certificate; current clamp; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 | - | ±0.5% | ±(3% + 8 digit) |
| MPI-540-PL | WMPLMPI540 | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | - | - | checks conductors polarization | - | WS-03 test adapter; calibration certificate; current clamp; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 | - | ±0.5% | ±(3% + 8 digit) |
| MPI-540PVS-PL | WMPLMPI540PVS | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | for solar panels, photovoltaics | - | checks conductors polarization | - | WS-03 test adapter; calibration certificate; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 | - | ±0.5% | ±(3% + 8 digit) |
| MPI-540PVS-IRM-1 | WMPLMPI540PVSIRM1 | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | for solar panels, photovoltaics | - | checks conductors polarization | - | - | calibration certificate; USB cable; cable for supplying from car lighter socket; crocodile clips x3; solar radiation and temperature meter IRM-1; carrying strap; carrying case; test leads x3; 15m long test lead (blue); 30m long test lead (red); test probe x3; multi-function meter of electrical system parameters MPI-540PVS-PL | ±0.5% | ±(3% + 8 digit) |
| MPI-540S-PL | WMPLMPI540S | 50k...250M/500M/999M/2G/9.99G | RCD tripping time, frequency, reactive electric energy, active electric energy, apparent electric energy, harmonics, short circuit loop impedance, reactive power, active power, apparent power, AC voltage, illuminance, RCD tripping current, insulation resistance, earthing resistance, THD | LCD TFT 7" | yes | 800x480 | 50/100/250/500/1k | 0...500 | 0...99.9k | rechargeable battery Li-Ion 11,1V 3400mAh x1 | IP51 | Bluetooth; USB; WiFi | CAT III 500V CAT IV 300V EN 61010 | - | - | checks conductors polarization | - | WS-03 test adapter; calibration certificate; USB cable; cable for supplying from car lighter socket; 3 crocodile clips; carrying strap; case; test leads ( 3pcs.); 15m long test lead (blue); 30m long test lead (red); test probe x3 | - | ±0.5% | ±(3% + 8 digit) |