| Manufacturer | BESEL |
| Type of motor | AC |
| Electrical connection | screw terminals |
| Insulation class | F |
| Colour | RAL 5010 |
| Supply voltage | 230V AC |
| Symbol | IP rating | Operating temperature | Power | Nom. rotat. speed | Number of poles | Inom | Nom. torque | Shaft axis lift | Mounting | Features |
|---|---|---|---|---|---|---|---|---|---|---|
| [°C] | [kW] | [rpm] | [A] | [Nm] | ||||||
| SEH56-2A | IP54 | -15...40 | 0.09 | 2840 | 2 | 0.95 | 0.3 | 56 | arms | continuous operation S1 |
| SEH56-2B | IP54 | -15...40 | 0.12 | 2860 | 2 | 1 | 0.4 | 56 | arms | continuous operation S1 |
| SEH56-2C | IP54 | -15...40 | 0.18 | 2830 | 2 | 1.5 | 0.61 | 56 | arms | continuous operation S1 |
| SEH56-4A | IP54 | -15...40 | 0.06 | 1410 | 4 | 0.65 | 0.41 | 56 | arms | continuous operation S1 |
| SEH56-4B | IP54 | -15...40 | 0.09 | 1420 | 4 | 0.95 | 0.61 | 56 | arms | continuous operation S1 |
| SEH56-4C | IP54 | -15...40 | 0.12 | 1400 | 4 | 1.2 | 0.81 | 56 | arms | continuous operation S1 |
| SEH63-2A | IP54 | -15...40 | 0.18 | 2840 | 2 | 1.4 | 0.61 | 63 | arms | continuous operation S1 |
| SEH63-2B | IP54 | -15...40 | 0.25 | 2840 | 2 | 1.7 | 0.84 | 63 | arms | continuous operation S1 |
| SEH63-2C | IP54 | -15...40 | 0.37 | 2840 | 2 | 2.4 | 1.24 | 63 | arms | continuous operation S1 |
| SEH63-4A | IP54 | -15...40 | 0.12 | 1400 | 4 | 1.2 | 0.82 | 63 | arms | continuous operation S1 |
| SEH63-4B | IP54 | -15...40 | 0.18 | 1400 | 4 | 1.5 | 1.23 | 63 | arms | continuous operation S1 |
| SEH63-4C | IP54 | -15...40 | 0.25 | 1360 | 4 | 1.9 | 1.76 | 63 | arms | continuous operation S1 |
| SEH71-2B | IP54 | -15...40 | 0.55 | 2820 | 2 | 3.6 | 1.86 | 71 | arms | continuous operation S1 |
| SEH71-2C | IP54 | -15...40 | 0.75 | 2820 | 2 | 4.9 | 2.54 | 71 | arms | continuous operation S1 |
| SEH71-4A | IP54 | -15...40 | 0.25 | 1350 | 4 | 2.4 | 1.77 | 71 | arms | continuous operation S1 |
| SEH71-4B | IP54 | -15...40 | 0.37 | 1370 | 4 | 2.9 | 2.6 | 71 | arms | continuous operation S1 |
| SEKH71-4B1 | IP54 | -15...40 | 0.37 | 1370 | 4 | 2.9 | 2.6 | 71 | flange | continuous operation S1 |
| SEH71-4C | IP54 | -15...40 | 0.55 | 1350 | 4 | 4.2 | 3.89 | 71 | arms | continuous operation S1 |
| SEH80-2B | IP54 | -15...40 | 1.1 | 2780 | 2 | 7 | 3.78 | 80 | arms | continuous operation S1 |
| SEH80-2C | IP54 | -15...40 | 1.5 | 2740 | 2 | 9.1 | 5.23 | 80 | arms | continuous operation S1 |
| SEH80-2D | IP54 | -15...40 | 2 | 2780 | 2 | 13 | 6.87 | 80 | arms | continuous operation S1 |
| SEH80-4A | IP54 | -15...40 | 0.55 | 1380 | 4 | 3.9 | 3.81 | 80 | arms | continuous operation S1 |
| SEH80-4B | IP54 | -15...40 | 0.75 | 1410 | 4 | 4.8 | 5.08 | 80 | arms | continuous operation S1 |
| SEH80-4C | IP54 | -15...40 | 1.1 | 1370 | 4 | 7.2 | 7.67 | 80 | arms | continuous operation S1 |
| SEH90-2S | IP54 | -15...40 | 1.5 | 2740 | 2 | 9.1 | 5.23 | 90 | arms | continuous operation S1 |
| SEH90-2L | IP54 | -15...40 | 2 | 2780 | 2 | 13 | 6.87 | 90 | arms | continuous operation S1 |
| SEH90-4S | IP54 | -15...40 | 1.1 | 1370 | 4 | 7.2 | 7.7 | 90 | arms | continuous operation S1 |
| SEH90-4L | IP54 | -15...40 | 1.3 | 1370 | 4 | 9 | 9.1 | 90 | arms | continuous operation S1 |
| SEHR90-2S | IP54 | -15...40 | 1.5 | 2800 | 2 | 9 | 5.12 | 90 | arms | frame made of drawn tube; continuous operation S1 |
| SEHR90-4S | IP54 | -15...40 | 1.1 | 1380 | 4 | 7.5 | 7.6 | 90 | arms | frame made of drawn tube; continuous operation S1 |
| SEMH56-2A | IP54 | -15...40 | 0.06 | 2800 | 2 | 0.85 | 0.21 | 56 | arms | increased starting torque; continuous operation S1 |
| SEMH56-2B | IP54 | -15...40 | 0.09 | 2790 | 2 | 1 | 0.31 | 56 | arms | increased starting torque; continuous operation S1 |
| SEMH56-2C | IP54 | -15...40 | 0.12 | 2800 | 2 | 1.3 | 0.41 | 56 | arms | increased starting torque; continuous operation S1 |
| SEMH56-4A | IP54 | -15...40 | 0.04 | 1350 | 4 | 0.6 | 0.28 | 56 | arms | increased starting torque; continuous operation S1 |
| SEMH56-4B | IP54 | -15...40 | 0.06 | 1390 | 4 | 0.9 | 0.41 | 56 | arms | increased starting torque; continuous operation S1 |
| SEMKH56-4B | IP54 | -15...40 | 0.06 | 1390 | 4 | 0.9 | 0.41 | 56 | flange | increased starting torque; continuous operation S1 |
| SEMH56-4C | IP54 | -15...40 | 0.09 | 1340 | 4 | 1.1 | 0.64 | 56 | arms | increased starting torque; continuous operation S1 |
| SEMH63-2A | IP54 | -15...40 | 0.12 | 2800 | 2 | 1.3 | 0.41 | 63 | arms | increased starting torque; continuous operation S1 |
| SEMH63-2B | IP54 | -15...40 | 0.18 | 2780 | 2 | 1.6 | 0.62 | 63 | arms | increased starting torque; continuous operation S1 |
| SEMH63-2C | IP54 | -15...40 | 0.25 | 2760 | 2 | 1.9 | 0.87 | 63 | arms | increased starting torque; continuous operation S1 |
| SEMH63-4A | IP54 | -15...40 | 0.09 | 1430 | 4 | 1.2 | 0.63 | 63 | arms | increased starting torque; continuous operation S1 |
| SEMH63-4B | IP54 | -15...40 | 0.12 | 1360 | 4 | 1.25 | 0.84 | 63 | arms | increased starting torque; continuous operation S1 |
| SEMH63-4C | IP54 | -15...40 | 0.18 | 1320 | 4 | 1.8 | 1.3 | 63 | arms | increased starting torque; continuous operation S1 |
| SEMH71-2A | IP54 | -15...40 | 0.25 | 2720 | 2 | 2 | 0.88 | 71 | arms | increased starting torque; continuous operation S1 |
| SEMH71-2B | IP54 | -15...40 | 0.37 | 2760 | 2 | 3 | 1.28 | 71 | arms | increased starting torque; continuous operation S1 |
| SEMH71-2C | IP54 | -15...40 | 0.55 | 2780 | 2 | 3.6 | 1.89 | 71 | arms | increased starting torque; continuous operation S1 |
| SEMH71-4B | IP54 | -15...40 | 0.25 | 1340 | 4 | 2.5 | 1.78 | 71 | arms | increased starting torque; continuous operation S1 |
| SEMKH71-4B | IP54 | -15...40 | 0.25 | 1340 | 4 | 2.5 | 1.78 | 71 | flange | increased starting torque; continuous operation S1 |
| SEMH71-4C | IP54 | -15...40 | 0.37 | 1320 | 4 | 3.2 | 2.68 | 71 | arms | increased starting torque; continuous operation S1 |
| SEMH80-2A | IP54 | -15...40 | 0.55 | 2780 | 2 | 4.1 | 1.89 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMH80-2B | IP54 | -15...40 | 0.75 | 2800 | 2 | 5 | 2.56 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMH80-2C | IP54 | -15...40 | 1.1 | 2780 | 2 | 6.4 | 3.75 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMH80-2D | IP54 | -15...40 | 1.5 | 2700 | 2 | 10 | 5.31 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMH80-4A | IP54 | -15...40 | 0.37 | 1350 | 4 | 3 | 2.62 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMH80-4B | IP54 | -15...40 | 0.55 | 1360 | 4 | 3.9 | 3.86 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMKH80-4B | IP54 | -15...40 | 0.55 | 1360 | 4 | 3.9 | 3.86 | 80 | flange | increased starting torque; continuous operation S1 |
| SEMH80-4C | IP54 | -15...40 | 0.75 | 1340 | 4 | 5.6 | 5.35 | 80 | arms | increased starting torque; continuous operation S1 |
| SEMH90-2S | IP54 | -15...40 | 1.1 | 2800 | 2 | 6.4 | 3.81 | 90 | arms | increased starting torque; continuous operation S1 |
| SEMH90-2L | IP54 | -15...40 | 1.5 | 2700 | 2 | 10.2 | 5.31 | 90 | arms | increased starting torque; continuous operation S1 |
| SEMH90-4S | IP54 | -15...40 | 0.75 | 1340 | 4 | 5.6 | 5.19 | 90 | arms | increased starting torque; continuous operation S1 |
| SEMH90-4L | IP54 | -15...40 | 1.1 | 1300 | 4 | 7.8 | 8.08 | 90 | arms | increased starting torque; continuous operation S1 |
| SEMHR90-2S | IP54 | -15...40 | 1.1 | 2760 | 2 | 7 | 3.8 | 90 | arms | frame made of drawn tube; increased starting torque; continuous operation S1 |
| SEMHR90-2L | IP54 | -15...40 | 1.5 | 2750 | 2 | 9.4 | 5.2 | 90 | arms | frame made of drawn tube; increased starting torque; continuous operation S1 |
| SEMHR90-4S | IP54 | -15...40 | 0.75 | 1380 | 4 | 5.5 | 5.2 | 90 | arms | frame made of drawn tube; increased starting torque; continuous operation S1 |
| SEMHR90-4L | IP54 | -15...40 | 1.1 | 1360 | 4 | 8.1 | 7.7 | 90 | arms | frame made of drawn tube; increased starting torque; continuous operation S1 |
| SEMHR90-4M | IP54 | -15...40 | 1.5 | 1340 | 4 | 11 | 10.7 | 90 | arms | frame made of drawn tube; increased starting torque; continuous operation S1 |
| SEHZ90-2L | IP54 | - | 2.2 | 2810 | 2 | 12.8 | 7.48 | 90 | arms | frame made of drawn tube |
| SEH90-4SF | IP55 | - | 1.1 | 1370 | - | - | - | - | - | - |