Socket; AC supply; SCHAFFNER / TE Connectivity

Manufacturer
Operating temperature-25...85°C
Connectorsocket
Type of connectorAC supply
Rated voltage250V AC
Kindmale
Conform to the normCSA Std C22.2 No. 8-13
GB/T15287
GB/T15288
IEC EN 60939-3
UL 60939-3
TypeC14 (E)
Capacitance Cx220nF
Fuse size5x20mm
Resistance1MΩ
Caution!fuses not included
Manufacturer seriesFN9262
Trade namepower entry module, power module
Symbol Mechanical mounting Design Current rating Capacitance Cy Leakage current Inductance Leads Panel thickness Lead length Leads dimensions
[A] [nF] [A] [mH] [mm] [m] [mm]
FN9262-10-06 for panel mounting, screw fuse x2 filter 10 2.2 310µ 1.15 connectors - - 6.3x0.8
FN9262-10-07 for panel mounting, screw fuse x2 filter 10 2.2 310µ 1.15 cables - 0.16 -
FN9262-1-06 for panel mounting, screw fuse x2 filter 1 2.2 310µ 40 connectors - - 6.3x0.8
FN9262-1-07 for panel mounting, screw fuse x2 filter 1 2.2 310µ 40 cables - 0.16 -
FN9262-2-06 for panel mounting, screw fuse x2 filter 2 2.2 310µ 20 connectors - - 6.3x0.8
FN9262-2-07 for panel mounting, screw fuse x2 filter 2 2.2 310µ 20 cables - 0.16 -
FN9262-4-06 for panel mounting, screw fuse x2 filter 4 2.2 310µ 7 connectors - - 6.3x0.8
FN9262-4-07 for panel mounting, screw fuse x2 filter 4 2.2 310µ 7 cables - 0.16 -
FN9262-6-06 for panel mounting, screw fuse x2 filter 6 2.2 310µ 3 connectors - - 6.3x0.8
FN9262-6-07 for panel mounting, screw fuse x2 filter 6 2.2 310µ 3 cables - 0.16 -
FN9262A-10-06 for panel mounting, screw fuse x2 safety class filter 10 4.7 70p 1.15 connectors - - 6.3x0.8
FN9262A-10-07 for panel mounting, screw fuse x2 safety class filter 10 4.7 70p 1.15 cables - 0.16 -
FN9262A-1-06 for panel mounting, screw fuse x2 safety class filter 1 4.7 70p 40 connectors - - 6.3x0.8
FN9262A-1-07 for panel mounting, screw fuse x2 safety class filter 1 4.7 70p 40 cables - 0.16 -
FN9262A-2-06 for panel mounting, screw fuse x2 safety class filter 2 4.7 70p 20 connectors - - 6.3x0.8
FN9262A-2-07 for panel mounting, screw fuse x2 safety class filter 2 4.7 70p 20 cables - 0.16 -
FN9262A-4-06 for panel mounting, screw fuse x2 safety class filter 4 4.7 70p 7 connectors - - 6.3x0.8
FN9262A-4-07 for panel mounting, screw fuse x2 safety class filter 4 4.7 70p 7 cables - 0.16 -
FN9262A-6-06 for panel mounting, screw fuse x2 safety class filter 6 4.7 70p 3 connectors - - 6.3x0.8
FN9262A-6-07 for panel mounting, screw fuse x2 safety class filter 6 4.7 70p 3 cables - 0.16 -
FN9262B-10-06 for panel mounting, screw fuse x2 medical class filter 10 - 0 1.15 connectors - - 6.3x0.8
FN9262B-10-07 for panel mounting, screw fuse x2 medical class filter 10 - 0 1.15 cables - 0.16 -
FN9262B-1-06 for panel mounting, screw fuse x2 medical class filter 1 - 0 40 connectors - - 6.3x0.8
FN9262B-1-07 for panel mounting, screw fuse x2 medical class filter 1 - 0 40 cables - 0.16 -
FN9262B-2-06 for panel mounting, screw fuse x2 medical class filter 2 - 0 20 connectors - - 6.3x0.8
FN9262B-2-07 for panel mounting, screw fuse x2 medical class filter 2 - 0 20 cables - 0.16 -
FN9262B-4-06 for panel mounting, screw fuse x2 medical class filter 4 - 0 7 connectors - - 6.3x0.8
FN9262B-4-07 for panel mounting, screw fuse x2 medical class filter 4 - 0 7 cables - 0.16 -
FN9262B-6-06 for panel mounting, screw fuse x2 medical class filter 6 - 0 3 connectors - - 6.3x0.8
FN9262B-6-07 for panel mounting, screw fuse x2 medical class filter 6 - 0 3 cables - 0.16 -
FN9262S-10-06 for panel mounting, snap-in fuse x2 filter 10 2.2 310µ 1.15 connectors 0.6...1.5 - 6.3x0.8
FN9262S-10-07 for panel mounting, snap-in fuse x2 filter 10 2.2 310µ 1.15 cables 0.6...1.5 0.16 -
FN9262S-1-06 for panel mounting, snap-in fuse x2 filter 1 2.2 310µ 40 connectors 0.6...1.5 - 6.3x0.8
FN9262S-1-07 for panel mounting, snap-in fuse x2 filter 1 2.2 310µ 40 cables 0.6...1.5 0.16 -
FN9262S-2-06 for panel mounting, snap-in fuse x2 filter 2 2.2 310µ 20 connectors 0.6...1.5 - 6.3x0.8
FN9262S-2-07 for panel mounting, snap-in fuse x2 filter 2 2.2 310µ 20 cables 0.6...1.5 0.16 -
FN9262S-4-06 for panel mounting, snap-in fuse x2 filter 4 2.2 310µ 7 connectors 0.6...1.5 - 6.3x0.8
FN9262S-4-07 for panel mounting, snap-in fuse x2 filter 4 2.2 310µ 7 cables 0.6...1.5 0.16 -
FN9262S-6-06 for panel mounting, snap-in fuse x2 filter 6 2.2 310µ 3 connectors 0.6...1.5 - 6.3x0.8
FN9262S-6-07 for panel mounting, snap-in fuse x2 filter 6 2.2 310µ 3 cables 0.6...1.5 0.16 -
FN9262SA-10-06 for panel mounting, snap-in fuse x2 safety class filter 10 4.7 70p 1.15 connectors 0.6...1.5 - 6.3x0.8
FN9262SA-1-06 for panel mounting, snap-in fuse x2 safety class filter 1 4.7 70p 40 connectors 0.6...1.5 - 6.3x0.8
FN9262SA-2-06 for panel mounting, snap-in fuse x2 safety class filter 2 4.7 70p 20 connectors 0.6...1.5 - 6.3x0.8
FN9262SA-4-06 for panel mounting, snap-in fuse x2 safety class filter 4 4.7 70p 7 connectors 0.6...1.5 - 6.3x0.8
FN9262SA-6-06 for panel mounting, snap-in fuse x2 safety class filter 6 4.7 70p 3 connectors 0.6...1.5 - 6.3x0.8
FN9262SB-10-06 for panel mounting, snap-in fuse x2 medical class filter 10 - 0 1.15 connectors 0.6...1.5 - 6.3x0.8
FN9262SB-10-07 for panel mounting, snap-in fuse x2 medical class filter 10 - 0 1.15 cables 0.6...1.5 0.16 -
FN9262SB-1-06 for panel mounting, snap-in fuse x2 medical class filter 1 - 0 40 connectors 0.6...1.5 - 6.3x0.8
FN9262SB-1-07 for panel mounting, snap-in fuse x2 medical class filter 1 - 0 40 cables 0.6...1.5 0.16 -
FN9262SB-2-06 for panel mounting, snap-in fuse x2 medical class filter 2 - 0 20 connectors 0.6...1.5 - 6.3x0.8
FN9262SB-2-07 for panel mounting, snap-in fuse x2 medical class filter 2 - 0 20 cables 0.6...1.5 0.16 -
FN9262SB-4-06 for panel mounting, snap-in fuse x2 medical class filter 4 - 0 7 connectors 0.6...1.5 - 6.3x0.8
FN9262SB-4-07 for panel mounting, snap-in fuse x2 medical class filter 4 - 0 7 cables 0.6...1.5 0.16 -
FN9262SB-6-06 for panel mounting, snap-in fuse x2 medical class filter 6 - 0 3 connectors 0.6...1.5 - 6.3x0.8
FN9262SB-6-07 for panel mounting, snap-in fuse x2 medical class filter 6 - 0 3 cables 0.6...1.5 0.16 -