| Manufacturer | AUTONICS |
| Controlled parameter | temperature |
| Mounting | on panel |
| Kind of inputs | 0...100mV, 0...10V, 0...20mA, 0...5V, 4...20mA, universal |
| Input properties | analogue voltage; current analog; RTD; thermocouple |
| Kind of temperature sensor | Cu100, Cu50, JPt100, Ni120, Pt100, Pt50, thermocouple B, thermocouple C, thermocouple E, thermocouple G, thermocouple J, thermocouple K, thermocouple L, thermocouple N, thermocouple PLII, thermocouple R, thermocouple S, thermocouple T, thermocouple U |
| Regulation for output 1 | ON-OFF, P, PD, PI, PID |
| Display | LED x2 |
| The programming method | foil keypad |
| Operating temperature | -10...50°C |
| IP rating | IP65 |
| Disp. 2 height | 12mm |
| Controlled parameter range | -1999...9999 |
| Disp. height 1 | 14.6mm |
| Mounting hole | 45x92mm |
| Body dim. | 48x96x70.5mm |
| Manufacturer series | TK4H |
| Type of automation module | regulator |
| Symbol | Supply voltage | Usup | Kind of OUT1 | Kind of OUT3 | Kind of OUT2 |
|---|---|---|---|---|---|
| [V AC] | [V DC] | ||||
| TK4H-14CC | 100...240 | - | analogue, SSR | alarm, SPST-NO | transfer, SSR |
| TK4H-14CR | 100...240 | - | analogue, SSR | alarm, SPST-NO | alarm, SPST-NO |
| TK4H-14RC | 100...240 | - | SPST-NO | alarm, SPST-NO | transfer, SSR |
| TK4H-14RR | 100...240 | - | SPST-NO | alarm, SPST-NO | alarm, SPST-NO |
| TK4H-14SR | 100...240 | - | SSR | alarm, SPST-NO | alarm, SPST-NO |
| TK4H-12CC | 24 | 24...48 | analogue, SSR | alarm, SPST-NO | transfer, SSR |
| TK4H-12CN | 24 | 24...48 | analogue, SSR | alarm, SPST-NO | - |
| TK4H-12CR | 24 | 24...48 | analogue, SSR | alarm, SPST-NO | alarm, SPST-NO |
| TK4H-12RC | 24 | 24...48 | SPST-NO | alarm, SPST-NO | transfer, SSR |
| TK4H-12RN | 24 | 24...48 | SPST-NO | alarm, SPST-NO | - |
| TK4H-12RR | 24 | 24...48 | SPST-NO | alarm, SPST-NO | alarm, SPST-NO |
| TK4H-14CN | 100...240 | - | analogue, SSR | alarm, SPST-NO | - |
| TK4H-14RN | 100...240 | - | SPST-NO | alarm, SPST-NO | - |
| TK4H-14SN | 100...240 | - | SSR | alarm, SPST-NO | - |
| TK4H-22CC | 24 | 24...48 | analogue, SSR | alarm x2, SPST-NO | transfer, SSR |
| TK4H-22CN | 24 | 24...48 | analogue, SSR | alarm x2, SPST-NO | - |
| TK4H-22CR | 24 | 24...48 | analogue, SSR | alarm x2, SPST-NO | alarm, SPST-NO |
| TK4H-22RC | 24 | 24...48 | SPST-NO | alarm x2, SPST-NO | transfer, SSR |
| TK4H-22RN | 24 | 24...48 | SPST-NO | alarm x2, SPST-NO | - |
| TK4H-22RR | 24 | 24...48 | SPST-NO | alarm x2, SPST-NO | alarm, SPST-NO |
| TK4H-24CC | 100...240 | - | analogue, SSR | alarm x2, SPST-NO | transfer, SSR |
| TK4H-24CN | 100...240 | - | analogue, SSR | alarm x2, SPST-NO | - |
| TK4H-24CR | 100...240 | - | analogue, SSR | alarm x2, SPST-NO | alarm, SPST-NO |
| TK4H-24RC | 100...240 | - | SPST-NO | alarm x2, SPST-NO | transfer, SSR |
| TK4H-24RN | 100...240 | - | SPST-NO | alarm x2, SPST-NO | - |
| TK4H-24RR | 100...240 | - | SPST-NO | alarm x2, SPST-NO | alarm, SPST-NO |
| TK4H-24SC | 100...240 | - | SSR | alarm x2, SPST-NO | transfer, SSR |
| TK4H-24SN | 100...240 | - | SSR | alarm x2, SPST-NO | - |
| TK4H-24SR | 100...240 | - | SSR | alarm x2, SPST-NO | alarm, SPST-NO |
| TK4H-A2CC | 24 | 24...48 | analogue, SSR | alarm x2, transfer, SPST-NO | transfer, SSR |
| TK4H-A2CN | 24 | 24...48 | analogue, SSR | alarm x2, transfer, SPST-NO | - |
| TK4H-A2CR | 24 | 24...48 | analogue, SSR | alarm x2, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-A2RC | 24 | 24...48 | SPST-NO | alarm x2, transfer, SPST-NO | transfer, SSR |
| TK4H-A2RN | 24 | 24...48 | SPST-NO | alarm x2, transfer, SPST-NO | - |
| TK4H-A2RR | 24 | 24...48 | SPST-NO | alarm x2, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-A4CC | 100...240 | - | analogue, SSR | alarm x2, transfer, SPST-NO | transfer, SSR |
| TK4H-A4CN | 100...240 | - | analogue, SSR | alarm x2, transfer, SPST-NO | - |
| TK4H-A4CR | 100...240 | - | analogue, SSR | alarm x2, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-A4RC | 100...240 | - | SPST-NO | alarm x2, transfer, SPST-NO | transfer, SSR |
| TK4H-A4RN | 100...240 | - | SPST-NO | alarm x2, transfer, SPST-NO | - |
| TK4H-A4RR | 100...240 | - | SPST-NO | alarm x2, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-A4SC | 100...240 | - | SSR | alarm x2, transfer, SPST-NO | transfer, SSR |
| TK4H-A4SN | 100...240 | - | SSR | alarm x2, transfer, SPST-NO | - |
| TK4H-A4SR | 100...240 | - | SSR | alarm x2, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-B2CC | 24 | 24...48 | analogue, SSR | alarm x2, RS485 Modbus RTU, SPST-NO | transfer, SSR |
| TK4H-B2CN | 24 | 24...48 | analogue, SSR | alarm x2, RS485 Modbus RTU, SPST-NO | - |
| TK4H-B2CR | 24 | 24...48 | analogue, SSR | alarm x2, RS485 Modbus RTU, SPST-NO | alarm, SPST-NO |
| TK4H-B2RC | 24 | 24...48 | SPST-NO | alarm x2, RS485 Modbus RTU, SPST-NO | transfer, SSR |
| TK4H-B2RN | 24 | 24...48 | SPST-NO | alarm x2, RS485 Modbus RTU, SPST-NO | - |
| TK4H-B2RR | 24 | 24...48 | SPST-NO | alarm x2, RS485 Modbus RTU, SPST-NO | alarm, SPST-NO |
| TK4H-B4CC | 100...240 | - | analogue, SSR | alarm x2, RS485 Modbus RTU, SPST-NO | transfer, SSR |
| TK4H-B4CN | 100...240 | - | analogue, SSR | alarm x2, RS485 Modbus RTU, SPST-NO | - |
| TK4H-B4CR | 100...240 | - | analogue, SSR | alarm x2, RS485 Modbus RTU, SPST-NO | alarm, SPST-NO |
| TK4H-B4RC | 100...240 | - | SPST-NO | alarm x2, RS485 Modbus RTU, SPST-NO | transfer, SSR |
| TK4H-B4RN | 100...240 | - | SPST-NO | alarm x2, RS485 Modbus RTU, SPST-NO | - |
| TK4H-B4RR | 100...240 | - | SPST-NO | alarm x2, RS485 Modbus RTU, SPST-NO | alarm, SPST-NO |
| TK4H-B4SC | 100...240 | - | SSR | alarm x2, RS485 Modbus RTU, SPST-NO | transfer, SSR |
| TK4H-B4SN | 100...240 | - | SSR | alarm x2, RS485 Modbus RTU, SPST-NO | - |
| TK4H-B4SR | 100...240 | - | SSR | alarm x2, RS485 Modbus RTU, SPST-NO | alarm, SPST-NO |
| TK4H-R2CC | 24 | 24...48 | analogue, SSR | alarm, transfer, SPST-NO | transfer, SSR |
| TK4H-R2CN | 24 | 24...48 | analogue, SSR | alarm, transfer, SPST-NO | - |
| TK4H-R2CR | 24 | 24...48 | analogue, SSR | alarm, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-R2RC | 24 | 24...48 | SPST-NO | alarm, transfer, SPST-NO | transfer, SSR |
| TK4H-R2RN | 24 | 24...48 | SPST-NO | alarm, transfer, SPST-NO | - |
| TK4H-R2RR | 24 | 24...48 | SPST-NO | alarm, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-R4CC | 100...240 | - | analogue, SSR | alarm, transfer, SPST-NO | transfer, SSR |
| TK4H-R4CN | 100...240 | - | analogue, SSR | alarm, transfer, SPST-NO | - |
| TK4H-R4CR | 100...240 | - | analogue, SSR | alarm, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-R4RC | 100...240 | - | SPST-NO | alarm, transfer, SPST-NO | transfer, SSR |
| TK4H-R4RN | 100...240 | - | SPST-NO | alarm, transfer, SPST-NO | - |
| TK4H-R4RR | 100...240 | - | SPST-NO | alarm, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-R4SC | 100...240 | - | SSR | alarm, transfer, SPST-NO | transfer, SSR |
| TK4H-R4SN | 100...240 | - | SSR | alarm, transfer, SPST-NO | - |
| TK4H-R4SR | 100...240 | - | SSR | alarm, transfer, SPST-NO | alarm, SPST-NO |
| TK4H-T2CC | 24 | 24...48 | analogue, SSR | alarm, RS485 Modbus RTU | transfer, SSR |
| TK4H-T2CN | 24 | 24...48 | analogue, SSR | alarm, RS485 Modbus RTU | - |
| TK4H-T2CR | 24 | 24...48 | analogue, SSR | alarm, RS485 Modbus RTU | alarm, SPST-NO |
| TK4H-T2RC | 24 | 24...48 | SPST-NO | alarm, RS485 Modbus RTU | transfer, SSR |
| TK4H-T2RN | 24 | 24...48 | SPST-NO | alarm, RS485 Modbus RTU | - |
| TK4H-T2RR | 24 | 24...48 | SPST-NO | alarm, RS485 Modbus RTU | alarm, SPST-NO |
| TK4H-T4CC | 100...240 | - | analogue, SSR | alarm, RS485 Modbus RTU | transfer, SSR |
| TK4H-T4CN | 100...240 | - | analogue, SSR | alarm, RS485 Modbus RTU | - |
| TK4H-T4CR | 100...240 | - | analogue, SSR | alarm, RS485 Modbus RTU | alarm, SPST-NO |
| TK4H-T4RC | 100...240 | - | SPST-NO | alarm, RS485 Modbus RTU | transfer, SSR |
| TK4H-T4RN | 100...240 | - | SPST-NO | alarm, RS485 Modbus RTU | - |
| TK4H-T4RR | 100...240 | - | SPST-NO | alarm, RS485 Modbus RTU | alarm, SPST-NO |
| TK4H-T4SC | 100...240 | - | SSR | alarm, RS485 Modbus RTU | transfer, SSR |
| TK4H-T4SN | 100...240 | - | SSR | alarm, RS485 Modbus RTU | - |
| TK4H-T4SR | 100...240 | - | SSR | alarm, RS485 Modbus RTU | alarm, SPST-NO |