Wire: control cable; IGUS

Wire: control cable; IGUS, CF5.02.36, CF5.03.15, CF5.03.18, CF5.03.25, CF5.05.02, CF5.05.03 |EN|
Manufacturer
Type of wirecontrol cable
Rated volt.300V/500V
Kind of coreCu
Corestranded
Operating temperature5...70°C
Insulation colourgreen
Featuresself-supporting
Resistance toUV rays, torsion, most of oils
Applicationindustrial applications;
power chain;
control for machines;
rapid handling systems;
indoor
Wire insulation materialPVC
Kind of materialno flame propagation
Shield structureunshielded
CPR standardno classification
InformationThe UL Label and Mark on full factory packaging only
Symbol Øext. cable Core marking Number of cores Core section Conform to the norm Earth core
[mm] [mm2]
CF5.02.36 15 colours without colour repetition 36 0.25 UL 10492 UL 2570 none
CF5.03.15 10 colours without colour repetition 15 0.34 UL 10492 UL 2570 none
CF5.03.18 11.5 colours without colour repetition 18 0.34 UL 10492 UL 2570 none
CF5.05.02 6 black, numbered 2 0.5 UL 10492 UL 2570 none
CF5.05.03 6 black, numbered + ground wire 3 0.5 UL 10492 UL 2570 yellow-green
CF5.05.04 6.5 black, numbered + ground wire 4 0.5 UL 10492 UL 2570 yellow-green
CF5.05.05 7 black, numbered + ground wire 5 0.5 UL 10492 UL 2570 yellow-green
CF5.05.07 8 black, numbered + ground wire 7 0.5 UL 10492 UL 2570 yellow-green
CF5.05.12 11 black, numbered + ground wire 12 0.5 UL 10492 UL 2570 yellow-green
CF5.05.18 13 black, numbered + ground wire 18 0.5 UL 10492 UL 2570 yellow-green
CF5.05.25 16 black, numbered + ground wire 25 0.5 UL 10492 UL 2570 yellow-green
CF5.05.30 18 black, numbered + ground wire 30 0.5 UL 10492 UL 2570 yellow-green
CF5.07.03 6.5 black, numbered + ground wire 3 0.75 UL 11113 UL 2570 yellow-green
CF5.07.04 7 black, numbered + ground wire 4 0.75 UL 11113 UL 2570 yellow-green
CF5.07.05 7.5 black, numbered + ground wire 5 0.75 UL 11113 UL 2570 yellow-green
CF5.07.07 9 black, numbered + ground wire 7 0.75 UL 11113 UL 2570 yellow-green
CF5.07.12 12.5 black, numbered + ground wire 12 0.75 UL 11113 UL 2570 yellow-green
CF5.07.18 15 black, numbered + ground wire 18 0.75 UL 11113 UL 2570 yellow-green
CF5.07.25 17.5 black, numbered + ground wire 25 0.75 UL 11113 UL 2570 yellow-green
CF5.07.36 22 black, numbered + ground wire 36 0.75 UL 11113 UL 2570 yellow-green
CF5.07.42 24 black, numbered + ground wire 42 0.75 UL 11113 UL 2570 yellow-green
CF5.10.03 6.5 black, numbered + ground wire 3 1 UL 11113 UL 2570 yellow-green
CF5.10.04 7 black, numbered + ground wire 4 1 UL 11113 UL 2570 yellow-green
CF5.10.05 8 black, numbered + ground wire 5 1 UL 11113 UL 2570 yellow-green
CF5.10.07 9.5 black, numbered + ground wire 7 1 UL 11113 UL 2570 yellow-green
CF5.10.12 13 black, numbered + ground wire 12 1 UL 11113 UL 2570 yellow-green
CF5.10.18 16.5 black, numbered + ground wire 18 1 UL 11113 UL 2570 yellow-green
CF5.10.25 19.5 black, numbered + ground wire 25 1 UL 11113 UL 2570 yellow-green
CF5.15.03 7.5 black, numbered + ground wire 3 1.5 UL 11113 UL 2570 yellow-green
CF5.15.04 8 black, numbered + ground wire 4 1.5 UL 11113 UL 2570 yellow-green
CF5.15.05 9 black, numbered + ground wire 5 1.5 UL 11113 UL 2570 yellow-green
CF5.15.07 10.5 black, numbered + ground wire 7 1.5 UL 11113 UL 2570 yellow-green
CF5.15.12 15 black, numbered + ground wire 12 1.5 UL 11113 UL 2570 yellow-green
CF5.15.18 19.5 black, numbered + ground wire 18 1.5 UL 11113 UL 2570 yellow-green
CF5.15.25 21.5 black, numbered + ground wire 25 1.5 UL 11113 UL 2570 yellow-green
CF5.15.36 26.5 black, numbered + ground wire 36 1.5 UL 11113 UL 2570 yellow-green
CF5.25.04 10 black, numbered + ground wire 4 2.5 UL 11113 UL 2570 yellow-green
CF5.25.05 11 black, numbered + ground wire 5 2.5 UL 11113 UL 2570 yellow-green
CF5.25.07 13 black, numbered + ground wire 7 2.5 UL 11113 UL 2570 yellow-green
CF5.25.12 18.5 black, numbered + ground wire 12 2.5 UL 11113 UL 2570 yellow-green
CF5.25.18 23.5 black, numbered + ground wire 18 2.5 UL 11113 UL 2570 yellow-green
CF5.25.25 27.5 black, numbered + ground wire 25 2.5 UL 11113 UL 2570 yellow-green